125 W 4TH ST 90013

Certificate Information: 125 W 4TH ST 90013

Application / Permit
17047-20000-00502
Plan Check / Job No.
B17VN04180
Group
Building
Type
Swimming-Pool/Spa
Sub-Type
Apartment
Primary Use
(4) Pool/Spa - Public
Work Description
(N) 14'-6" x 31'-9" Pool and 14'-6" x 10'-0" Spa per Standard Plan # 268 & Engineering detail # 660 on top of 12th floor roof deck of (E) Apartment Building..
Permit Issued
Issued on 5/29/2018
Issuing Office
Valley
Current Status
Permit Finaled on 5/3/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/28/2017 APPLICANT
Assigned to Plan Check Engineer 4/27/2017 OMID HEDAYAT
Corrections Issued 5/2/2017 OMID HEDAYAT
Quality Review Completed 5/3/2017 ABDUL CHEGENI
Building Plans Picked Up 5/11/2017 APPLICANT
Disabled Access Plans Picked Up 5/11/2017 APPLICANT
Applicant returned to address corrections 5/29/2018 OMID HEDAYAT
Plan Check Approved 5/29/2018 OMID HEDAYAT
Issued 5/29/2018 LADBS
Permit Finaled 5/3/2021 ERNESTO CORRAL

Permit Application Clearance Information

"D" conditions Cleared 6/6/2017 DANIEL SKOLNICK
"Q" conditions Cleared 6/6/2017 DANIEL SKOLNICK
Eng Process Fee Ord 176,300 Cleared 6/6/2017 JOHN LIN
Sewer availability Cleared 6/6/2017 JOHN LIN
ZA Case Cleared 6/6/2017 DANIEL SKOLNICK
Project located in CRA area Cleared 7/26/2017 CRAIG BULLOCK
HPOZ Cleared 8/7/2017 LAMBERT GIESSINGER
HPOZ Cleared 8/7/2017 LAMBERT GIESSINGER
HPOZ Cleared 8/7/2017 LAMBERT GIESSINGER
Historic monument Cleared 8/7/2017 LAMBERT GIESSINGER
DAS Clearance Cleared 5/7/2018 OMID HEDAYAT
Public Swimming Pool approval Cleared 5/29/2018 LACDHS APPROVED

Contact Information

Contractor Addison Pools Inc; Lic. No.: 753417-B 4363 WOODMAN AVENUE      SHERMAN OAKS, CA 91423
Engineer Lacher, Todd Lee; Lic. No.: C67656 1201 N TUSTIN AVE      ANAHEIM, CA 92807

Inspector Information

KATY RAMIREZ, (213) 213-5353 Office Hours: 7:00-8:00 AM MON-FRI
JEROME BLACKWOOD, (213) 213-5353 Office Hours: 7:00-8:00 AM MON-FRI
PAUL BAZERKANIAN, (213) 213-5353 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 6/5/2018 Partial Approval NICK DANERI
Pre-Gunite 6/5/2018 Partial Approval NICK DANERI
Deputy Shotcrete 6/11/2018 Conditional Approval NICK DANERI
Enclosure/Fence 10/29/2019 Not Ready for Inspection DANIEL COLLINS
Enclosure/Fence 10/30/2019 Partial Approval RUSSELL BONVOULOIR
Excavation/Setback/Form/Re-Bar 4/27/2020 Approved DANIEL COLLINS
Final 4/27/2020 Conditional Approval DANIEL COLLINS
Pre-Gunite 4/27/2020 Approved DANIEL COLLINS
SGSOV-Seismic Gas S/O Valve 4/27/2020 SGSOV Approved DANIEL COLLINS