2244-2244 1/2 S RIDGELEY DR 90016
Certificate Information: 2244-2244 1/2 S RIDGELEY DR 90016
- Application / Permit
- 21010-10000-03846
- Plan Check / Job No.
- B21LA14063
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- ePlan NEW 1-STORY, 2 DETACHED ADU's PER STATE LAW CONNECTED IN MIDDLE WITH STAIRS FOR THE ROOFTOP DECK. “The LID clearance has been deferred. Approval for LID requirements shall be obtained from LASAN prior to the issuance of the Certificate of Occupancy.”
- Permit Issued
- Issued on 3/7/2022
- Issuing Office
- Current Status
- CofO Issued on 9/13/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
Submitted | 7/28/2021 | APPLICANT |
Assigned to Plan Check Engineer | 7/30/2021 | VIVIAN LAO |
Corrections Issued | 7/31/2021 | PRANITA SHAH |
Applicant returned to address corrections | 11/15/2021 | JOE VO |
Applicant returned to address corrections | 11/23/2021 | VIVIAN LAO |
Applicant returned to address corrections | 12/1/2021 | VIVIAN LAO |
Plan Check Approved | 12/7/2021 | ZAW HAN |
Issued | 3/7/2022 | APPLICANT |
CofO in Progress | 9/13/2023 | JOSE AVILA |
CofO Issued | 9/13/2023 | DEROLD HAUFF |
Permit Finaled | 9/13/2023 | DEROLD HAUFF |
Permit Application Clearance Information
Address approval | Cleared | 8/12/2021 | RENZ SORIANO |
Eng Process Fee Ord 176,300 | Cleared | 8/12/2021 | RENZ SORIANO |
Hydrant and Access approval | Cleared | 9/30/2021 | RUEL COLE |
Roof/Waste drainage to street | Cleared | 11/10/2021 | THAN WIN |
Sewer availability | Cleared | 11/18/2021 | PAMELA TENEZA |
Contact Information
Contractor | Marcos Construction Inc; Lic. No.: 686859-B | P O BOX 65552 LOS ANGELES, CA 90065 |
Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 5832 JAMIESON AVE ENCINO, CA 91316 |
Inspector Information
STUART CHAPMAN, (213) 202-3126 | Office Hours: 7:00-8:00 AM MON-FRI |
ARTHUR NEGRETE, (213) 202-3126 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
No Data Available. |
Inspection Request History
Excavation/Setback/Form/Re-Bar | 5/10/2022 | Approved | JOSE AVILA |
Footing/Foundation/Slab | 5/10/2022 | Approved | JOSE AVILA |
Floor/Roof Diaphrgm/Shear Wall | 6/8/2022 | Partial Approval | JOSE AVILA |
Deputy Wood Construction | 7/12/2022 | Conditional Approval | RUBEN SALAS |
Floor/Roof Diaphrgm/Shear Wall | 7/12/2022 | Conditional Approval | JOSE AVILA |
Wood Frame | 7/12/2022 | Approved | JOSE AVILA |
ELECTRICAL-Rough | 8/24/2022 | Approved | JOSE AVILA |
BUILDING-Rough-Frame | 9/14/2022 | Conditional Approval | JOSE AVILA |
HVAC-Rough | 9/14/2022 | Partial Approval | JOSE AVILA |
Interior/Exterior Lathing | 9/14/2022 | Approved | JOSE AVILA |
PLUMBING-Rough | 9/14/2022 | Approved | JOSE AVILA |
Insulation | 10/13/2022 | Approved | JOSE AVILA |
Drywall Nailing | 10/19/2022 | Approved | JOSE AVILA |
Sewer | 3/10/2023 | Approved | JOSE AVILA |
ELECTRICAL-Final | 6/29/2023 | Corrections Issued | JOSE AVILA |
HVAC-Final | 6/29/2023 | Corrections Issued | JOSE AVILA |
PLUMBING-Final | 6/29/2023 | Corrections Issued | JOSE AVILA |
ELECTRICAL-Final | 7/27/2023 | Partial Approval | ALIZAH MAYAGOITIA |
HVAC-Final | 7/27/2023 | Approved | ALIZAH MAYAGOITIA |
MERV13>=Final | 7/27/2023 | Approved | ALIZAH MAYAGOITIA |
PLUMBING-Final | 7/27/2023 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
Service/Power Release | 7/27/2023 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
BUILDING-Rough-Frame | 8/7/2023 | Approved | JOSE AVILA |
ELECTRICAL-Final | 8/7/2023 | Approved | JOSE AVILA |
Final | 8/7/2023 | Corrections Issued | JOSE AVILA |
MERV13>=Rough | 8/7/2023 | Approved | JOSE AVILA |
PLUMBING-Final | 8/7/2023 | Approved | JOSE AVILA |
SGSOV-Seismic Gas S/O Valve | 8/7/2023 | SGSOV Approved | JOSE AVILA |
Service/Power Release | 8/7/2023 | Approved | JOSE AVILA |
Smoke Detectors | 8/7/2023 | Approved | JOSE AVILA |
Verify Sprinkler Sign Off | 8/7/2023 | Approved | JOSE AVILA |
Final | 9/13/2023 | OK to Issue CofO | JOSE AVILA |